Minicom Setup
If you don’t have minicom installed, please do that first sudo apt install minicom
. In this example we are using ttyUSB0
as the device the VectorNav-200 is connected to.
sudo minicom -o -D /dev/ttyUSB0
To enable sending carriage returns and local echo on (
CTRL-A
thenE
)
Enter the cOnfigure Minicom menu (
CTRL-A
thenO
) and set the following:Desired baud rate
HW flow control OFF
SW flow control ON
Vectornav setup commands
The commands below can be sent via your favorite telnet program (i.e. Minicom, Screen, coolTerm, etc)
Code Block |
---|
# Configure VectorNav - turn off async messages on both ports TX1 and TX2
$VNWRG,06,0,1*XX
$VNWRG,06,0,2*XX |
Code Block |
---|
# Configure VectorNav - set baud rates of port TX1
$VNWRG,05,115200,1*XX |
Code Block |
---|
# Configure VectorNav - set baud rates of port TX2
$VNWRG,05,115200,2*XX |
Code Block |
---|
# Configure VectorNav - Only turn on standard NMEA (GPRMC) messages
$VNWRG,101,3,1,0,0,01*XX |
Vectornav setup script
The script can be run in Linux using:
./setup_vectornav.sh
The script is located here: https://drive.google.com/open?id=1QM8gX_eVcWawmcTPyzSGADgFphtBtkhE